Your Trusted Ammeter Calibration Provider

Micro Precision is an ISO/IEC 17025:2017 accredited calibration provider with NIST-traceable reference standards and a network of more than 50 laboratories operating worldwide. Ammeters measure electrical current across circuits ranging from bench-top test setups to industrial power systems, and even minor measurement drift undermines the safety and quality decisions built on those readings.

Micro Precision provides ISO/IEC 17025:2017 accredited ammeter calibration with NIST-traceable standards, supporting aerospace, defense, medical device manufacturing, automotive, and general manufacturing industries. Our global network of more than 50 laboratories delivers consistent, documented calibration results accepted by quality auditors and regulatory bodies across regulated industries worldwide.

Ammeter calibration is one part of Micro Precision’s broader electrical calibration services portfolio, supported by the same accredited standards and documented traceability chain used across our complete instrument calibration services. Quality teams managing multiple electrical test instruments rely on this consistency to simplify audits, vendor qualification, and calibration record management across their entire test equipment inventory

Fill out our Ammeter calibration service request form

Why Ammeter Calibration Matters

Ammeter calibration matters because current measurement accuracy directly affects electrical safety, product quality, and regulatory compliance. An ammeter that drifts out of tolerance produces readings that appear valid but mask overcurrent conditions, mislead pass/fail testing decisions, and create non-conformance findings during ISO/IEC 17025:2017-based quality audits.

Regulatory frameworks reinforce this requirement directly. ANSI/NCSL Z540.3 requires documented, objective evidence of calibration for measuring and test equipment used in regulated processes, while ISO 10012 establishes measurement management system requirements including calibration intervals and traceability controls. For quality managers and compliance officers, a valid calibration certificate with clear traceability is not optional.

Procurement officers rely on accredited calibration vendors to reduce sourcing risk and simplify audit preparation, while lab technicians depend on accurate readings to trust their test results. Micro Precision supports both priorities with standard and rush turnaround options and both in-lab and on-site calibration service, backed by ISO/IEC 17025:2017 accreditation.

Ensure Accurate Ammeter Calibration

Accurate ammeter calibration requires a structured process that verifies current readings against known references and corrects any deviation found. Micro Precision follows a documented calibration workflow for every ammeter received, performed under the controls required by our ISO/IEC 17025:2017 accreditation.

The process for each instrument includes:

  1. Receipt and inspection — instrument condition, current range, and connector or clamp type are verified on arrival
  2. Performance testing — the ammeter is tested against laboratory reference standards traceable to NIST to establish as-found measurement status
  3. Adjustment — systematic measurement errors are corrected using calibration methods appropriate to the instrument’s type and current range
  4. Post-adjustment verification — measurements confirm the instrument performs within required parameters after calibration
  5. Documentation — a certificate of calibration is issued, documenting the calibration date, interval, standards used, and as-found and as-left data
  6. Return — the calibrated ammeter is packaged and returned with its certificate of calibration

Standard and rush turnaround options are available for time-critical programs. Contact our team to discuss current lead times and priority scheduling.


Our Calibration Options

Micro Precision offers both in-lab and on-site ammeter calibration to match your equipment configuration, testing environment, and program timeline. Choosing between the two options depends primarily on whether the ammeter is a portable bench instrument or a panel-mounted unit integrated into a larger system.

In-Lab Calibration
Ship your ammeter to one of our accredited laboratories for full-capability calibration under controlled conditions. In-lab service supports the complete range of calibration documentation options, including ISO/IEC 17025:2017 accredited certificates with NIST-traceable measurement results.

On-Site Calibration
For panel-mounted and installed ammeters that cannot be removed from service, Micro Precision sends qualified calibration technicians directly to your facility. On-site calibration reduces downtime, eliminates shipping risk, and keeps production and test operations running while delivering the same documentation options available for in-lab service.

Rush Turnaround
Standard and rush turnaround options are available for both in-lab and on-site service. Contact our team to discuss current lead times and priority scheduling.

Ammeter Types We Calibrate

Micro Precision calibrates a variety of ammeter types and instruments from the manufacturers used across electrical test, maintenance, and quality control environments.

  • Analog ammeters
  • Digital ammeters
  • Clamp-on and current-clamp ammeters
  • Panel-mount ammeters installed in switchgear, control panels, and power distribution equipment
  • DC ammeters used in battery, power supply, and industrial test applications
  • AC ammeters used in motor, generator, and power distribution testing

If your ammeter model is not listed here, contact our team to confirm support. Micro Precision also provides digital multimeter calibration and clamp meter calibration for related electrical test equipment used alongside ammeters in the field and lab.

Calibration Service Levels Offered

Type of ServiceTraceableTraceable with DataAccredited (ISO:IEC 17025:2017, Z540.3)
Calibrated to manufacturers specifications traceable to SI Units   
ISO 9000 Compliant   
Calibration certificates, data, maintained on secure web based tool (CDM)   
Detailed calibration certificates and calibration stickers   
Instrument adjustment (if found out of tolerance)   
ANSI/NCSL Z540-1 compliant  
Calibration Data  
Logo from Accreditation body, Expanded Measurement Uncertainty 
ANSI/NCSL Z540.3 compliant 

Ammeter Calibration Services

Micro Precision delivers ISO/IEC 17025:2017 accredited ammeter calibration with NIST traceability, documented certificates, and on-site service options for panel-mounted and installed instruments. With more than 50 laboratories serving aerospace, defense, medical, automotive, and manufacturing industries, Micro Precision provides the accredited calibration record your quality program requires. Submit a request today to discuss your ammeter inventory, service level requirements, and turnaround options.

Please complete our quick Ammeter equipment calibration & repair service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)

DescriptionManufacturerModel
AEMC 2129.19 Clamp-On Ammeter for AC Current Mini 05AEMC2129.19
Agilent Technologies 4155A Semiconductor Parameter AnalyzerAgilent
Agilent Technologies 428A MilliammeterAgilent
Agilent Technologies 428B MilliammeterAgilent428B
Agilent Technologies 4304B DC Volt/AmmeterAgilent4304B
Ammon Instruments 94-462-8 AmmeterAmmon Instruments94-462-8
Amprobe 300 Ammeter Clamp-On ACVAmprobe300
Amprobe ACD-3A Clamp On Meter Volt/Amp/Ohmmeter - ACD3AAmprobeACD-3A
Amprobe ACDC-600A Clamp On Digital AC/DC Ammeter - ACDC600AAmprobeACDC-600A
Amprobe ACDC-600AT Clamp On Digital AC/DC Ammeter - ACDC-600ATAmprobeACDC-600AT
Amprobe ACDC-610 Clamp On Digital AC/DC Ammeter - ACDC610AmprobeACDC-610
Amprobe AD105A Ammeter - TRMS DigitalAmprobeAD105A
Amprobe AM-2BB Ammeter / VOM / Multimeter - AM2BBAmprobeAM-2BB
Amprobe AM-6 Ampmeter / VOM - AM6AmprobeAM-6
Amprobe LH41A AC/DC Clamp-on AmmeterAmprobeLH41A
Amprobe PAA1500 Ammeter AC RecorderAmprobePAA1500
Amprobe RS5 Ammeter / Clamp On AC Volt AC Current Resistance Rotary MeterAmprobeRS5
Amprobe Ultra Ammeter - Clamp-OnAmprobeULTRA
API 503K AmmeterAPI503K
AW SPERRY DSA-1000 Ammeter Digital AC Volt-Ohm (DigiSnap)AW SperryDSA-1000
AW Sperry DSA-2413 AC Digital Leakage AmmeterAW SperryDSA-2413
AW SPERRY DSA-400 Volt-Ohm-Ammeter Digital DigiSnap Snap-Around AC Current 400A DC Volts 1000VAW SperryDSA-400
AW SPERRY DSA-450TRMS Volt-Ohm-Ammeter Digital DigiSnap Snap-Around AC Current 400A DC Volts 1000VAW SperryDSA-450TRMS
AW Sperry DSA-7610 Volt-Ohm-Ammeter Digital DigiSnap Snap-Around 3.5 Digit with Auto-Off AC Current 300A AC Volts 500VAW SperryDSA-7610
AW SPERRY M100 Volt-Ammeter - Clamp On - 100A / 600V - Snap 6 Series - Snap-Around - M-100AW SperryM100
AW SPERRY M300 Volt-Ammeter - Clamp On - 300A / 600V - Snap 6 Series - Snap-Around - M-300AW SperryM300
AW SPERRY OHM150 Volt-Ohm Ammeter Clamp On Amps AC 150A Volts AC 600V Snap 6 Series Snap-AroundAW SperryOHM150
AW SPERRY OHM300 Volt-Ohm / Ammeter / Clamp-on Meter - 300A / 600V - Snap 6 Series - Snap-AroundAW SperryOHM300
AW SPERRY OHM50 Volt-Ohm - Ammeter - Clamp On - 50A / 600V - Snap 6 Series - Snap-AroundAW SperryOHM50
AW SPERRY OHM525 Volt-Ohm - Ammeter - Clamp On - 125A / 300V - Snap 6 Series - Snap-AroundAW SperryOHM525
AW Sperry SJ-100 AC Volt Ammeter - Mini Probe Clamp OnAW SperrySJ-100
AW Sperry SJ-25 AC Volt Ammeter - Mini Probe Clamp OnAW SperrySJ-25
AW Sperry SJ-50 AC Volt Ammeter - Mini Probe Clamp OnAW SperrySJ-50
AW Sperry SPR-100 Ammeter / Clamp-on Meter - Rotary Scale Snap-Around - 300A AC - Snap 8 SeriesAW SperrySPR-100
AW SPERRY SPR-1030 Clamp On / Volt-Ohm-Ammeter Rotary Scale Snap-Around 1000 Amps AC - 750 Volts AC - 25 Ohm Mid-Scale - SPR1030AW SperrySPR-1030
AW Sperry SPR-200 Volt-Ammeter - Rotary Scale Snap-Around - 300A AC / 600V AC - Snap 8 SeriesAW SperrySPR-200
AW SPERRY SPR-300 PLUS Volt-Ohm-Ammeter / Clamp-on Meter - Rotary Scale Snap-Around - 600V AC / 600A - 2K ResistanceAW SperrySPR-300 PLUS
AW Sperry SPR-300 Volt-Ohm-Ammeter / Clamp-on Meter - Rotary Scale Snap-Around - 300A AC / 600V AC / 25Ohm - Mid-Scale - Snap 8 SeriesAW SperrySPR-300
AW Sperry SPR-300CL Volt-Ohm-Ammeter - Rotary Scale Snap-Around - 300A AC / 600V / 25Ohm - Mid-Scale - Snap 8 SeriesAW SperrySPR-300CL
AW Sperry SPR-311 AC Volt-Ohm-Ammeter - Rotary Scale Snap-AroundAW SperrySPR-311
AW SPERRY SPR-311 PLUS AC Volt-Ohm-Ammeter - Rotary Scale Snap-AroundAW SperrySPR-311 PLUS
AW Sperry SPR-910 Ammeter - Rotary Scale Snap-Around - 900A AC - Snap 9 SeriesAW SperrySPR-910
AW Sperry SPR-920 Volt-Ammeter - Rotary Scale Snap-Around - 900A AC / 750V AC - Self Contained - Snap 9 SeriesAW SperrySPR-920
AW Sperry SPR-930 Volt-Ohm-Ammeter / Clamp-on Meter - Rotary Scale Snap-Around - Snap 9 SeriesAW SperrySPR-930
AW Sperry SPR-931 Volt-Ohm-Ammeter / Clamp-on Meter - Rotary Scale Snap-Around - 900A AC / 750V AC - Self Contained - 25Ohm - Mid-Scale - Snap 9 SeriesAW SperrySPR-931
AW Sperry SR-150 Volt-Ammeter - 150A AC / 600V AC - Snap 5 SeriesAW SperrySR-150
AW Sperry SR-25 Volt-Ammeter - 25A AC / 600V AC - Snap 5 SeriesAW SperrySR-25
AW SPERRY SR-300 Volt-Ammeter - 300A AC / 600V AC - Snap 5 SeriesAW SperrySR-300
AW Sperry SR-50 Volt-Ammeter - 50A AC / 600V AC - Snap 5 SeriesAW SperrySR-50
B&K Precision 116 VOM AnalogBk Precision116
Electro Industries 1FAA5-250 Ammeter - ACElectro Industries1FAA5-250
FW Bell 1776 Current MeterFW Bell
General Electric 152121ECSJ8 Ammeter - DCGeneral Electric152121ECSJ8
General Electric 8DP-2 Ammeter - DCGeneral Electric8DP-2
General Electric DP2 Voltmeter / Ammeter - DC - DP-2General ElectricDP2
Hioki 9008 Clamp-On AmmeterHioki9008
Holt 250 Ammeter Calibrator - ACHolt250
Keithley 150A Microvolt - AmmeterKeithley150A
Keithley 486 Analog/Digital Picoammeter 5.5 digtKeithley486
Kikusui 115A Millivolt AmmeterKikusui115A
Lightstar KAA-08 Ammeter - 80 (W) x 80 (H)LightstarKAA-08
Mid-Continent Instruments 36029Mid-Continent Instruments
Olman 90703 AC/DC Ammeter - 600mAOlman90703
Olman 90704 AC/DC Ammeter - 6AOlman90704
Olman 90707 DC Ammeter - 1.5mAOlman90707
Olman 90708 DC Ammeter - 60mAOlman90708
Olman 90709 DC Ammeter - 6AOlman90709
Omega DP18-DC4-R2 Current MeterOmega EngineeringDP18-DC4-R2
Omega DP18-DV4-R2 Volt MeterOmega EngineeringDP18-DV4-R2
Pacer 800A AmmeterPacer800A
Powermetrix 2000 Amp High Voltage Litewire Fiber Optic AmmeterPowermetrix2000 Amp High Voltage Litewire
Racal Dana 2100 AmmeterRacal Dana2100
SensorLink Ampstik Plus True RMS Ammeter - 1 to 5000 AmpsSensorLinkAmpstik Plus
Simpson 0-1.0 AMSimpson Electric
Simpson 0-3.0 AMSimpson Electric
Simpson 1702 DC MicroammeterSimpson Electric1702
Simpson 3344 AmmeterSimpson Electric3344
Simpson 370 AmmeterSimpson Electric370
Simpson 378 AmmeterSimpson Electric378
Simpson 389 MilliammeterSimpson Electric389
Simpson 389-3L MilliammeterSimpson Electric389-3L
Triplett 420-G Milliammeter DCTriplett420-G
Tsuruga Electric NRP-83HL AC Amp MeterTsurugaNRP-83HL
Tsuruga NRC-120H AC Amp MeterTsurugaNRC-120H
Weston 100579 Ammeter ACWeston100579
Weston 370 Ammeter AC 2.5-5AWeston370
Weston 45 AmmeterWeston45
Weston 662 AmmeterWeston662
Weston 749 Clampmeter / Ammeter - AC - TYPE VA-1Weston749
Weston 901 Voltmeter DC / AMMETER DCWeston901
Weston P5 AmpmeterWestonP5
Yokogawa 1986 Ammeter - AC - AnalogYokogawa1986
Yokogawa 2011 DC AmmeterYokogawa2011
Yokogawa 2012-00 Portable Ammeter - DC / Voltmeter - 1mA-30A - 201200Yokogawa2012-00
Yokogawa 2013 AMMETER ACYokogawa2013
Yokogawa 2051 AmmeterYokogawa2051
Yokogawa 2062 AmmeterYokogawa2062
Yokogawa 2063 AmmeterYokogawa2063
Yokogawa 2353 Panel Meter / AmmeterYokogawa2353
Yokogawa 235300-04-10 Ammeter - ACYokogawa235300-04-10

Frequently Asked Questions

Ammeter calibration is the process of verifying and adjusting an ammeter’s current readings against NIST-traceable reference standards to confirm measurement accuracy. It matters because uncorrected drift in current measurements leads to faulty pass/fail decisions, safety risks in electrical systems, and non-conformance findings during ISO/IEC 17025:2017 quality audits.

Micro Precision recommends calibrating ammeters on an annual interval, consistent with common quality program requirements and ANSI/NCSL Z540.3 guidance for measuring and test equipment. Actual intervals depend on usage frequency, environmental conditions, and internal quality policy. Micro Precision documents a defined calibration interval on every certificate of calibration issued.

Micro Precision calibrates ammeters by comparing displayed current readings against NIST-traceable reference standards across multiple points in the instrument’s range, then adjusting the instrument to correct any deviation found. Technicians document as-found and as-left data, then issue a certificate of calibration confirming NIST traceability and accredited compliance.

NIST-traceable calibration means measurement results link through an unbroken chain to national standards maintained by the National Institute of Standards and Technology. ISO/IEC 17025:2017 accredited calibration adds independent, third-party verification that the laboratory’s processes, equipment, and personnel consistently produce those traceable results. Many quality programs require accredited documentation specifically.

Clamp-on, analog, and digital ammeters each require calibration methods matched to their measurement technology, but all receive the same accredited process: comparison against NIST-traceable references, documented adjustment, and a certificate of calibration. Micro Precision calibrates a variety of ammeter types, including clamp-on current probes and analog panel meters, under one accreditation scope.

ISO/IEC 17025:2017 accreditation and ANSI/NCSL Z540.3 compliance represent the highest calibration standards for pressure gauges, ensuring technical competence, measurement traceability to NIST, and documented measurement uncertainty. Choosing a lab accredited to these standards provides audit-ready documentation. Micro Precision maintains ISO/IEC 17025:2017 accreditation across its global calibration lab network.

Yes. Micro Precision provides on-site ammeter calibration for instruments integrated into panels, systems, or production lines where shipping is impractical. Qualified technicians travel to your facility with NIST-traceable reference standards and complete the same documented calibration process used in our accredited laboratories, including full certificate of calibration issuance.

Privacy Preference Center