Your Trusted Durometer Calibration Provider
Micro Precision is an ISO/IEC 17025:2017 accredited calibration provider delivering NIST-traceable durometer calibration services through a network of more than 50 labs. Quality managers, materials engineers, and procurement teams across rubber and plastics manufacturing, automotive, medical device, and footwear industries rely on Micro Precision to keep Shore A, Shore D, and Shore OO durometers within their required verification standards.
Durometers measure the surface hardness of elastomers, rubber, and plastics using a spring-loaded indenter and standard Shore hardness scales. This is a distinct measurement discipline from hardness testers, which measure the hardness of metals using Rockwell, Brinell, Vickers, or Leeb methods. Micro Precision maintains a separate, dedicated hardness tester calibration services page for metal testing equipment, so instrument owners can find the calibration program built specifically for their equipment type.
Micro Precision’s ISO/IEC 17025:2017 accreditation and NIST-traceable measurement chain give quality managers a documented, audit-ready calibration record for every Shore A, Shore D, or Shore OO durometer submitted, supporting compliance across rubber and plastics manufacturing, automotive, medical device, and footwear quality programs.
Why Durometer Calibration Matters
Durometer calibration matters because an uncalibrated instrument produces inaccurate Shore hardness readings that can mask material defects, leading to rejected parts, product failures, and non-conformance findings during an audit. Standardized Shore hardness scales and test methods govern how durometer readings are measured, and a durometer operating outside its verified accuracy range cannot confirm that a rubber, elastomer, or plastic part meets its specified hardness requirement.
ANSI/NCSL Z540.3 establishes the calibration program requirements that quality systems depend on to demonstrate measuring and test equipment is fit for use, giving quality managers the documented audit trail their ISO/IEC 17025:2017 and customer audits require. Materials engineers and lab technicians need confidence that indentation readings reflect the true hardness of the material tested, not drift in the durometer’s spring force or indenter.
Micro Precision’s calibration program applies standardized test methods and ANSI/NCSL Z540.3 program discipline to every Shore A, Shore D, and Shore OO durometer it services, giving rubber and plastics manufacturing, automotive, medical device, and footwear quality programs a calibration record they can trust.
Ensure Accurate Durometer Calibration
Ensuring accurate durometer calibration means verifying the instrument’s indentation reading against certified reference test blocks traceable to NIST across the applicable Shore scale, then documenting the results on a certificate of calibration. Micro Precision follows a defined sequence for every durometer received: inspect the instrument and indenter condition, apply certified test blocks across the applicable Shore A, Shore D, or Shore OO range, measure and record as-found and as-left results, adjust the instrument where needed, and issue documentation confirming the outcome.
Micro Precision calibrates durometers by inspecting the indenter and spring mechanism, verifying readings against NIST-traceable certified test blocks across the applicable Shore scale, recording as-found and as-left data, making adjustments where required, and issuing a certificate of calibration for every instrument.
Every durometer returns with a certificate of calibration documenting the verification performed and the standards referenced. Micro Precision offers standard turnaround alongside faster and quick turnaround options for durometers on a tight production or audit schedule, without compromising the verification steps required to maintain accredited calibration.
Our Calibration Options
Micro Precision offers durometer calibration through both in-lab and on-site service, giving quality managers and procurement officers a choice based on instrument type, production schedule, and downtime tolerance. In-lab calibration ships the durometer to one of Micro Precision’s ISO/IEC 17025:2017 accredited labs for full calibration under controlled conditions using certified reference test blocks.
On-site calibration brings a Micro Precision technician directly to the facility, verifying benchtop durometer test stands and portable handheld durometers without removing equipment from the production floor. On-site service is especially useful for facilities managing a variety of durometers across multiple production lines or quality control stations.
Both in-lab and on-site durometer calibration are backed by NIST traceability and documented on a certificate of calibration referencing applicable industry standards. Micro Precision provides standard turnaround for both service types, with faster and quick turnaround options available for time-sensitive audit or production needs across its network of more than 50 calibration labs.
Durometer Types We Calibrate
Micro Precision calibrates a variety of durometer types and scales used to measure the surface hardness of rubber, elastomers, and plastics across manufacturing and quality control environments.
- Shore A durometers, used for softer rubber, elastomers, and flexible plastics
- Shore D durometers, used for harder plastics and rigid rubber compounds
- Shore OO durometers, used for foams, gels, and very soft elastomeric materials
- Portable and handheld durometers, used for spot checks on production floors and in the field
- Benchtop durometer test stands, used for repeatable, high-volume laboratory testing
- Digital durometers, including models from ZwickRoell and Asker
- Dial (analog) durometers, including models from Rex Gauge, PTC Instruments, and Fowler
- Durometer test blocks and reference standards used to verify durometer accuracy
Durometer models not listed here are likely supported as well. Contact Micro Precision to confirm calibration availability for a specific make and model. Durometers measure the hardness of rubber, elastomers, and plastics using Shore scales, a distinct measurement discipline from hardness tester calibration services, which covers Rockwell, Brinell, Vickers, and Leeb testers used on metals. Durometer calibration is available as part of Micro Precision’s broader mechanical and dimensional calibration capabilities.
Calibration Service Levels Offered
Micro Precision offers durometer calibration at multiple service levels, from basic traceable certification to fully accredited documentation, so quality programs can match the level of rigor their industry requires.
| Type of Service | Traceable | Traceable with Data | Accredited (ISO:IEC 17025:2017, Z540.3) |
|---|---|---|---|
| Calibrated to manufacturers specifications traceable to SI Units | |||
| ISO 9000 Compliant | |||
| Calibration certificates, data, maintained on secure web based tool (CDM) | |||
| Detailed calibration certificates and calibration stickers | |||
| Instrument adjustment (if found out of tolerance) | |||
| ANSI/NCSL Z540-1 compliant | |||
| Calibration Data | |||
| Logo from Accreditation body, Expanded Measurement Uncertainty | |||
| ANSI/NCSL Z540.3 compliant |
Durometer Calibration Services
Micro Precision delivers ISO/IEC 17025:2017 accredited, NIST-traceable durometer calibration services for Shore A, Shore D, and Shore OO durometers, distinct from its dedicated hardness tester calibration program for metal testing equipment. Backed by a network of more than 50 calibration labs, quality managers get audit-ready documentation, materials engineers get trustworthy hardness data, and procurement officers get a single certified vendor for an entire durometer inventory. Request a calibration quote today and put a definitive standard behind your Shore hardness testing program.
Please complete our quick Durometer calibration & repair service request form, and a Micro Precision representative will reach out to you same-day during office hours, or within one business day after office hours. (Mon – Friday 8AM – 4PM PST)
Durometer Service
If you have any inquiries, or simply wish to connect with us, we'd love to hear from you! Please don't hesitate to reach out to us.
"*" indicates required fields
Frequently Asked Questions
Micro Precision calibrates a pressure controller by allowing the instrument and a certified reference standard to stabilize at ambient temperature, then comparing readings across multiple pressure set points and adjusting or documenting any deviation. A certificate of calibration confirming NIST traceability is issued with every instrument returned.
Durometers are typically calibrated on an industry-common interval, most often annually, adjusted for usage intensity, equipment type, and the quality system’s internal requirements. High-volume production durometers and instruments supporting automotive, medical device, or footwear quality programs often require more frequent verification between full calibrations.
Calibrating a durometer involves inspecting the indenter and spring mechanism, verifying readings against NIST-traceable certified test blocks across the applicable Shore scale, recording as-found and as-left results, making adjustments where needed, and issuing a certificate of calibration. Micro Precision performs this process for Shore A, Shore D, and Shore OO durometers.
Industry-recognized standard test methods define the Shore hardness scales and measurement procedures that govern durometer calibration accuracy, covering Shore A, Shore D, and Shore OO durometers used on rubber, elastomers, and plastics. Micro Precision calibrates durometers under its ISO/IEC 17025:2017 accreditation, applying established calibration methods and NIST-traceable reference standards for every instrument submitted.
Durometer calibration cost depends on the durometer type, Shore scale, and service level selected. Micro Precision does not publish flat-rate pricing because scope varies by make and model. Contact our team for a calibration quote specific to your durometer inventory.
NIST-traceable durometer calibration confirms measurement results connect to national reference standards through an unbroken chain of comparisons, while ISO/IEC 17025:2017 accreditation confirms the laboratory’s quality management system, technical competence, and measurement uncertainty practices meet an independently audited international standard. Micro Precision provides both: NIST traceability on every calibration and ISO/IEC 17025:2017 accreditation for its accredited service level.
A durometer test block is a certified reference standard with a known, fixed hardness value used to verify a durometer’s indentation reading during calibration. Micro Precision verifies durometers against NIST-traceable test blocks across the applicable Shore A, Shore D, or Shore OO range, confirming accuracy before issuing a certificate of calibration.
A durometer measures the surface hardness of rubber, elastomers, and plastics using a spring-loaded indenter and standard Shore A, Shore D, or Shore OO scales. A hardness tester measures the hardness of metals using Rockwell, Brinell, Vickers, or Leeb methods. Micro Precision calibrates both instrument types through separate, dedicated service programs.